Electronic Controls
Electric Valves
In current designs, the electronics controlling the valve are separate from the valve itself. The correct term to describe the valves is therefore electronically controlled electric valves. Since electric valves are assigned their function in the system by the software in their controller, an electric valve can be used anywhere in the system; as an expansion valve, discharge gas bypass valve, evaporator control valve, heat reclaim valve, head pressure control valve or crankcase pressure control valve.
| Number | Title | Date | Pages |
| Bulletin 100-9 | Electric Valves for Refrigerant Control | April 2007 | 16 |
| Bulletin 100-20 | Electric Expansion Valves – SER, SERI, SEHI | January 2012 | 20 |
| Bulletin 100-20-1 | Electric Expansion Valves – SER-AA, -A | September 2016 | 4 |
| Bulletin 100-20-4 | Electric Expansion Valve Type SERI-F | December 2012 | 4 |
| Bulletin 100-20-5 | Electric Expansion Valve Type SEH-P | March 2013 | 4 |
| Bulletin 100-20-6 | Unipolar Electric Expansion Valves | June 2014 | 4 |
| Bulletin 100-20-7 | SEHI-T Electric Expansion Valve | December 2015 | 4 |
| Bulletin 100-40 | Electric Pressure Regulating Valves – CDS Series | May 2012 | 16 |
| Bulletin 100-40-1 | (S)ORIT to CDS Conversion Kits | November 2012 | 4 |
| Bulletin 100-40-2 | A8/SPORT and A9 to CDS Valve | September 2015 | 4 |
| Bulletin 100-40-3 | Modulating 3-Way Valve Types MTW-9 and MTW-17 | July 2015 | 8 |
| Bulletin 100-60 | Electric Hot Gas Bypass Valves | August 2009 | 8 |
| Bulletin 100-80 | Sporlan Gas Cooler/Flash Gas Bypass Valves | September 2016 | 12 |
| Form 100-164 | Reducing Pressure Drop in Suction Lines | August 2002 | 4 |
| Form 100-202 | Direct and Indirect Savings Using Step Motor Valves | October 2004 | 4 |
| Form 100-302 | Proven Value of Electronic Suction Control | June 2010 | 4 |
| Form 100-304 | SER-C 2nd Generation – Proven Value of Electronic Superheat Control | November 2010 | 2 |
| Form 100-314 | Type SERI – Electronic Expansion Valve | December 2010 | 2 |
| Form 100-419 | Electronic Valves Poster | September 2014 | 1 |
| Form 100-439 | A8/SPORT TO CDS CONVERSION KIT Countermat | May 2015 | 1 |
| Form 100-503 | Uni-polar EEV with Internal Check | January 2017 | 2 |
| Form 100-504 | EEV with Serviceable Inlet Strainer | January 2017 | 2 |
| SD-218 | Step Motor Pressure Regulating Valve Types CDS(T)-2, -4, -7, -9, -16, -17 Installation and Servicing Instructions | June 2016 | 4 |
| SD-243 | SEI and SEH – Installation and Servicing Instructions | November 2012 | 4 |
| SD-244 | Electric Discharge Bypass Valves SDR-3, 3x and SDR-4 – Installation and Servicing Instructions | September 2003 | 4 |
| SD-286 | Step Motor Expansion Valves – Installation and Servicing Instructions | May 2016 | 4 |
| SD-287 | Step Motor Expansion Valves Installation Instructions | July 2010 | 4 |
| SD-297 | Installation Instructions: (S)ORIT to CDS Conversion Kit | May 2007 | 2 |
| SD-348 | Step Motor Expansion Valves Types SER-AA, -A, -B, -C, -D, & -E Installation and Servicing Instructions | June 2013 | 2 |
| SD-398 | Gas Cooler & Flash Gas Bypass Pressure Regulating Valves Installation and Servicing Instructions | September 2014 | 4 |
| SD-399 | A8/SPORT Pressure Regulator CDS Conversion Kits | January 2015 | 4 |
| SD-401 | Step Motor Expansion Valves Type SEH Installation and Servicing Instructions | November 2014 | 4 |
| SD-407 | Modulating 3-Way Valve | May 2015 | 2 |
| SD-420 | A9 Pressure Regulator CDS Conversion Kits | September 2015 | 4 |
| SD-425 | SEHI Installation Instructions | February 2018 | 4 |
| SD-426 | SER-AA, -A, -B, -C, -D Installation Instructions | February 2018 | 4 |
| SD-432 | Uni-polar EEV with Internal Check | December 2016 | 2 |
Controller Packages
The Sporlan Subcool Control is a simple means of controlling the Electronic Expansion Valve (EEV) on most liquid subcooling systems. The Subcool Control provides liquid temperature and superheat (pressure-temperature) control for most common refrigerants. It displays actual leaving liquid temperature, superheat, suction pressure, valve position, controller status, and alarms. It also allows manual control of the valve position.
| Number | Title | Date | Pages |
| Bulletin 100-50-5 | Kelvin II Series Electric Valve Controllers | January 2013 | 4 |
| Bulletin 100-50-5.1 | Superheat Control Installation and Operation Instructions | August 2016 | 36 |
| Bulletin 100-50-5.2 | Subcool Control – Installation and Operation Instructions | November 2012 | 22 |
| Bulletin 100-50-5.3 | Temperature Control – Installation and Operation Instructions | November 2012 | 16 |
| Bulletin 100-50-5.4rd | Secondary Fluid Control System with Remote Display | January 2016 | 20 |
| Bulletin 100-50-5.5 | Pressure Control – Installation and Operation Instructions | September 2013 | 20 |
| Bulletin 100-50-5.6 | Chiller Control – Installation and Operation Instructions | March 2014 | 28 |
| Bulletin 100-50-6.1 | PSK201 – Installation and Operating Instructions | September 2012 | 4 |
| Bulletin 100-50-6.2 | PSK203/223/233 – Installation and Operating Instructions | September 2012 | 8 |
| Bulletin 100-50-6.3 | PSK221/PSK231 – Installation and Operating Instructions | September 2012 | 8 |
| Bulletin 100-50-6.4 | PSK204 – Installation and Operating Instructions | September 2012 | 8 |
| Bulletin 100-50-6.5 | PSK214 – Installation and Operating Instructions | September 2012 | 12 |
| Bulletin 100-50-9 | S3C Series Case Controls | August 2017 | 4 |
| Bulletin 100-50-9.1 | S3C Series Case Controls – Installation and Operation Instructions | January 2018 | 146 |
| Form 100-335 | Subcool Control Electric Expansion Valve Controller | October 2011 | 2 |
| Forms 100-345 through 100-352 | PSK Refrigeration Controls | — | — |
| Form 100-359 | PSK Series Refrigeration Controllers for Low and Medium Temperature Applications | January 2014 | 4 |
| Form 100-364 | Secondary Fluid Valve and Controller For Secondary Fluid Refrigeration | January 2013 | 2 |
| Form 100-526 | S3C Controls and SSER or SPW valves | August 2017 | 2 |
| SD-324 | Superheat Control Quick Reference Guide | July 2016 | 2 |
| SD-358 | Sporlan Subcool Control – Quick Reference Guide | November 2012 | 2 |
| SD-358R | Subcool-O-Matic Replacement Instructions | June 2012 | 12 |
| SD-375 | Sporlan Temperature Control – Quick Reference Guide | September 2012 | 2 |
| SD-377 | Secondary Fluid Control Quick Reference Guide | January 2013 | 2 |
| SD-378 | Pressure Control Quick Reference Guide | July 2013 | 2 |
| SD-392 | Sporlan Chiller Control Quick Reference Guide | January 2014 | 2 |
| SD-429 | S3C Case Control Quick Reference Guide | August 2017 | 2 |
| SD-436 | S3C Display Module Quick Reference Guide | August 2017 | 2 |
| SD-437 | S3C Valve Module Quick Reference Guide | August 2017 | 2 |
| Program Download | PSK Competitive Cross Reference Program | — | — |
Control Boards
The Sporlan Cold Room Control (CRC) is a microprocessor-based system designed to precisely control refrigeration evaporators in walk-in coolers and freezers. It accurately controls refrigerant flow and provides a single point of reference for all control components. By monitoring pressure and temperatures, the CRC controls evaporator temperature more accurately and consistently than mechanical thermostatic expansion valves. In addition to superheat and room temperature control, the CRC is configured to control evaporator fans, the liquid line solenoid, defrost heaters, and defrost schedules. Valves and sensors may be purchased from Sporlan.
| Number | Title | Date | Pages |
| Bulletin 100-50-1 | Sporlan TCB – Temperature Control Board | December 2010 | 4 |
| Bulletin 100-50-4.1 | Cold Room Control Installation and Operating Instructions | March 2013 | 28 |
| SD-242 | Temperature Control Board – Installation and Servicing Instructions | February 2011 | 4 |
| SD-252 | Chiller Controller – Installation and Servicing Instructions | April 2008 | 4 |
| SD-255 | Pressure Controller | September 2001 | 2 |
| SD-257 | Superheat Controller – Installation and Servicing Instructions | March 2005 | 4 |
| SD-269 | Temperature Controller – Installation and Servicing Instructions | June 2003 | 4 |
| SD-273 | Two Valve Temperature Controller – Installation and Servicing Instructions | May 2003 | 4 |
| SD-302 | Cold Room Control, Quick Reference Guide | March 2013 | 8 |
Components and Accessories
The IB-G (interface board-global) has been developed to offer a highly configurable interface board that can accept 4-20 milliamp or 0-10 volt DC analog input signals. The IB-G will replace all of the obsolete legacy IB’s (IB1, IB2, IB3, IB6, and IB-ESX). The IB-G is designed to allow externally supplied control signals to control one or two Sporlan step motor valves including CDS evaporator control valves, SDR electric discharge bypass valves and SEI/SER/SEH electric expansion valves.
The LLS (Liquid Level Sensor) is an analog sensor that provides a way to monitor refrigerant levels in commercial A/C & R systems. Sporlan also offers temperature sensors and pressure transducers as inputs to our controller packages and control boards listed above.
| Number | Title | Date | Pages |
| Bulletin 100-50-2 | Sporlan IB Series Interface Boards IB1, IB2, IB3, IB6, IB ESX | July 2014 | 4 |
| Bulletin 100-50-2.1 | Sporlan IB-G Series Interface Board | September 2016 | 8 |
| Bulletin 100-50-7.1 | Liquid Level Sensors For Analog Type | May 2017 | 4 |
| Bulletin 100-50-3 | IB-ESX Series Interface Boards | January 2007 | 2 |
| SD-213 | SMA-12 – 12 VDC Bipolar Step Motor Actuator | January 2006 | 2 |
| SD-245 | Pressure Transducer and Temperature Sensor | April 2017 | 4 |
| SD-278 | Sporlan IB Series Interface Boards IB1, IB2, IB3, IB6, IB ESX Installation Instructions | July 2014 | 4 |
| SD-300 | IB ESX Series Interface Boards Installation Instructions | August 2007 | 2 |
| SD-362 | Pressure Transducer Reference Guide | April 2017 | 1 |
| SD-402 | IB-G Quick Reference Guide | March 2015 | 2 |
| SD-423 | RHT-2301, Air Temperature/Humidity Sensor Quick Reference Guide | April 2016 | 2 |
| SD-440 | Sensor-CT, Current Transformer Quick Reference Guide | May 2017 | 2 |